RATING
CHART FOR FULL, HALF & QUARTER SPEED MILL
DUTY DC MOTORS |
Frame |
Ref |
Speed
at |
Power at |
230 V |
460 V |
230 V |
460 V |
ILMD 802 |
F
H
Q |
900
405
160 |
1885
900
404 |
7.5
3.4
1.3 |
15.5
7.6
3.3 |
ILMD 803 |
F
H
Q |
800
365
145 |
1670
800
360 |
11
5
2 |
23
11
5 |
ILMD 804 |
F
H
Q |
725
330
135 |
1510
725
330 |
15
7
3 |
31
15
7.5 |
ILMD 806 |
F
H
Q |
650
300
125 |
1355
650
305 |
22
10
4 |
46
22
10.3 |
ILMD 808 |
F
H
Q |
575
265
115 |
1195
575
275 |
37
17
7.5 |
76.5
37
18 |
ILMD 810 |
F
H
Q |
550
255
110 |
1140
550
260 |
52
24
10.5 |
108
52
25 |
ILMD 812 |
F
H
Q |
515
240
110 |
1070
515
260 |
75
35
16 |
156
75
38 |
ILMD 814 |
F
H
Q |
500
230
105 |
1045
500
251 |
112
52
24 |
234
112
57 |
ILMD 816 |
F
H
Q |
480
222
97 |
1000
480
228 |
150
69
30 |
311
150
71 |
ILMD 818 |
F
H
Q |
435
201
90 |
905
435
212 |
187
87
39 |
389
187
92 |
| Legend: F - Full Speed; H -
Half Speed; Q - Quarter Speed |
Ratings declared above
are for forced ventilation only
For special requirements, please contact
the Marketing Department
The motors can also be offered with CACA
and CACW cooling with corresponding ratings
in frames 810 and above
|
OVERLOADS |
%
Load |
%
Rated Speed |
| at
230 V |
at
460 V |
300 |
200 |
100 |
250 |
250 |
140 |
200 |
300 |
200 |
|
|
PERMISSIBLE
STALL CURRENT FOR TENV MOTORS |
% Load |
Time |
300 |
15 Sec. |
200 |
30 Sec. |
100 |
2 Min. |
50 |
5 Min. |
40 |
60 Min. |
|
|
|