RATING
CHART |
|
Frame |
Power
Output |
Max.
Field Power (W) |
GD2
in
kg-m2 |
Weight
(kg) |
Max.
Mechanical Speed |
|
IC06
& ICW37A86 |
IC0666 |
|
kW |
Volt |
Speed |
kW |
Volt |
Speed |
IC06/
ICW37A86 |
IC0666 |
IC06 |
IC0666 |
ICW37A86 |
315S |
400 |
440 |
1500 |
240 |
440 |
1600 |
3500 |
2030 |
28 |
1750 |
2550 |
2700 |
2100 |
315M |
425 |
440 |
1250 |
280 |
440 |
1500 |
4100 |
2378 |
35 |
2060 |
2850 |
3000 |
315L |
425 |
440 |
1000 |
280 |
440 |
1250 |
4100 |
2552 |
43 |
2360 |
3150 |
3300 |
355K |
500 |
440 |
1600 |
- |
- |
- |
3400 |
- |
46 |
2700 |
- |
3300 |
1800 |
355S |
550 |
440 |
1250 |
320 |
440 |
1250 |
3900 |
2262 |
58 |
2750 |
3250 |
3400 |
355M |
575 |
440 |
1100 |
335 |
440 |
1100 |
4300 |
2494 |
63 |
2780 |
3700 |
3850 |
355L |
590 |
440 |
1000 |
350 |
440 |
1000 |
4400 |
2552 |
69 |
3100 |
4050 |
4200 |
400S |
700 |
440 |
1600 |
375 |
440 |
1500 |
4600 |
2668 |
92 |
3340 |
4340 |
4540 |
1750 |
400M |
750 |
440 |
1250 |
490 |
440 |
1500 |
5260 |
3051 |
115 |
3740 |
4740 |
4940 |
400L |
750 |
440 |
1000 |
490 |
440 |
1250 |
5600 |
3248 |
145 |
4140 |
5140 |
5340 |
450K |
800 |
600 |
1000 |
- |
- |
- |
6250 |
- |
168 |
5000 |
- |
6800 |
1600 |
450S |
815 |
600 |
900 |
475 |
600 |
1000 |
6600 |
3828 |
188 |
5300 |
7000 |
7200 |
450M |
835 |
600 |
800 |
475 |
600 |
900 |
7100 |
4118 |
212 |
5600 |
7300 |
7500 |
450L |
845 |
600 |
700 |
475 |
600 |
800 |
7800 |
4524 |
239 |
6000 |
7800 |
8000 |
500S |
950 |
600 |
1100 |
565 |
600 |
1400 |
5500 |
3190 |
278 |
5880 |
7380 |
7680 |
1500 |
500M |
1030 |
600 |
900 |
570 |
600 |
1100 |
6250 |
3625 |
349 |
6380 |
7900 |
8200 |
500L |
1030 |
600 |
700 |
570 |
600 |
900 |
6650 |
3850 |
440 |
7030 |
8600 |
8900 |
500G |
1030 |
600 |
600 |
570 |
600 |
750 |
7500 |
4350 |
508 |
7530 |
9230 |
9530 |
560K |
915 |
600 |
1130 |
- |
- |
- |
7000 |
- |
330 |
8000 |
- |
10000 |
1250 |
560S |
1090 |
600 |
750 |
650 |
600 |
1000 |
7500 |
4176 |
580 |
8700 |
10200 |
10500 |
560M |
1150 |
600 |
650 |
725 |
600 |
900 |
8000 |
4524 |
660 |
9100 |
10700 |
11000 |
560L |
1190 |
600 |
630 |
775 |
600 |
750 |
8500 |
4640 |
750 |
9500 |
11200 |
11500 |
560G |
1190 |
600 |
550 |
800 |
600 |
700 |
10500 |
6090 |
830 |
10150 |
12200 |
12500 |
630 |
Ratings
and Capacities on Demand |
710 |
Ratings
and Capacities on Demand |
800 |
Ratings
and Capacities on Demand |
900 |
Ratings
and Capacities on Demand |
Ratings are at an
ambient of 40°C and an altitude of 1000m
Refer to the deration chart for ambient and altitude
derations
For different speeds and voltages,
for other cooling and protection types mentioned
above, and for information on field weakening and
special requirements, please contact our Marketing
Department. |
FORCE COOLING
SPECIFICATIONS |
|
Frame |
IC06 |
IC0666 |
ICW37A86 |
Air Qty*
(m3/s) |
Pressure*
(mm WG) |
|
Top |
Side |
Side |
315 |
7.5kW/2P |
2.2kW/4P |
5.6kW/2P |
5.6kW/4P |
1.8 |
200 |
355 |
5.6kW/4P |
3.7kW/4P |
5.6kW/4P |
9.3kW/4P |
2.0 |
170 |
400 |
9.3kW/4P |
7.5kW/4P |
15kW/2P |
15kW/2P |
3.5 |
150 |
450 |
9.3kW/4P |
7.5kW/4P |
15kW/2P |
15kW/2P |
5.0 |
155 |
500 |
9.3kW/4P |
7.5kW/4P |
15kW/2P |
15kW/2P |
5.0 |
155 |
560 |
18.7kW/4P |
7.5kW/4P |
15kW/2P |
15kW/2P |
6.0 |
190 |
415V, 3ph, 50Hz, 2/4 Pole, AC Squirrel Cage Induction
Motor
* These values are for IP23, IC06 machines at the
inlet opening |
|